Seaward Supernova XE User Manual

Page 27

Advertising
background image

How to perform Automatic Tests

17

Default Sequence

When you first enter this menu all of the previous values are
displayed and one of the field descriptions is highlighted.

Use the cursor keys to highlight a field to be changed and press
Enter to select the desired option.

Test Parameter Fields

By selecting one of the test parameter fields from the Default

---------------DEFAULT SEQUENCE EDITOR----------------

OUTPUT LIMIT DUR NUM

SOCKET

230V

VISUAL

YES

1

EARTH BOND

4A 0.10

Ω 5 1

INSULATION

500V 0.50M

Ω 5 1

SUB LEAKAGE

SKIP

LEAKAGE

SKIP

TOUCH LEAKAGE

SKIP

POLARITY

SKIP

PERFORM TEST

-------------------------------LEAKAGE--------------------------------

OUTPUT

LIMIT

DURATION

NUMBER

230V

SKIP

2s

1

115V

0.25mA

5s

2

0.50mA

10s 3

0.75mA

30s

4

1.50mA

60s

5

2.25mA

120s 10

2.50mA

180s

15

3.00mA

UL

20

3.50mA

25

9.90mA

30

Advertising