Insulation test, Substitute leakage test, Leakage – Seaward Supernova XE User Manual

Page 85

Advertising
background image

Insulation Test

75

Accuracy..............................+/- 5% of reading, +/- 2 digits upto 5.00

Pass

Levels...........................................................................selectable

Misc.............................................4-wire measurement, floating earth

Insulation Test

Test Voltage * ............... 500V d.c. or 250V d.c. nominal (0.5M

Ω load)

Short Circuit Current............................................. 2mA d.c. maximum

Range.......................................................................... 100k

Ω - 100 MΩ

Resolution.......................................…..........……………......0.01 M

Accuracy..................... +/- 5% of reading, +/- 2 digits (100k

Ω - 20MΩ)

Pass Levels............................ 0.5M

Ω, 1.0MΩ, 2.0MΩ, 4.0MΩ,

7.0M

Substitute Leakage Test

Test Voltage * .....................................................................40V a.c. o/c

Display Range .......................................................... 0.1 - 20.0 mA a.c.

Resolution.............................................................................0.01mA

Accuracy..........................+/- 10% of reading, +/- 2 digits 1.00 - 20mA

Pass Levels.......................0.25mA, 0.5mA, 0.75mA, 2.5mA,

3.5mA, 7.0mA, 9.9mA, 15.0mA

Leakage

Range...........................................................................0.1mA - 10.0mA

Resolution.............................................................................0.01mA

Accuracy................................................ +/- 5% of reading, +/- 2 digits

Pass Levels.....................0.25mA, 0.5mA, 0.75mA, 1.5mA, 2.25mA,

2.5mA, 3.0mA, 3.5mA, 9.9mA