How to perform Automatic Tests

22

Review Test Results

Display the results from the test in tabular form:-

APPLIANCE :

A1212654673891

SITE
USER

: KITCHEN
: BOB

TESTCODE1 :

1027353823

TESTCODE 2

: 312169743A

TEST OUTPUT

LIMIT

RESULT

STATUS

EARTH BOND

25A

0.1ohms

0.99

PASS

EARTH BOND

25A

0.1ohms

0.98

PASS

INSULATION 500V 2Mohms

20.67 PASS

SUB LEAKAGE

7.5mA

<0.25

PASS

LOAD

2.00kVa

A fast key may illuminate to ‘view comments’.

Use the Red button to return to the previous menu.

Download Test Results

This option allows previous test results to be downloaded to either a
printer or a computer. The printer option allows a pass/fail label to be
printed on a compatible printer - see Chapter 6.

Main Menu

Return to the Main Menu.

Write Data to Smart Tag

This option can only be used when combined with the Seaward
Braincell/Smart Tag reader. Full details of this option can be found in
the manual which is supplied with every Braincell/Smart Tag reader.

Abort Actions

During an Automatic test, pressing the Red Button immediately stops

Advertising