Network requirements, Configuration procedure – H3C Technologies H3C WX3000E Series Wireless Switches User Manual

Page 27

Advertising
background image

17

Hardware

Ethernet interface configuration prerequisites

LSQM1WCMB0
LSQM1WCMD0
LSBM1WCM2A0
LSRM1WCM2A1
LSRM1WCM3A1

You configure Ethernet interfaces on the switch.

NOTE:

To log in to the access controller module from the switch, use the oap connect

slot

slot-number

command.

LSWM1WCM10
LSWM1WCM20

You configure Ethernet interfaces on the switch.

NOTE:

To log in to the access controller module from the switch, use the oap connect

slot 1

slot-number

system

system-name

command.

Wireless switches

WX3024E

Use the oap connect slot 0 command on the access controller engine to log
in to the switching engine.

Access controllers

WX6103

Use the oap connect slot 0 command on the active main control board to log
in to the switch interface board.

WX5002
WX5004

You configure GE interfaces on the access controller.

Network requirements

As shown in

Figure 5

, PC A is assigned to VLAN 5. PC B is assigned to VLAN 10. The PCs belong to

different IP subnets and cannot communicate with each other.
Configure VLAN interfaces on the AC and configure the PCs to enable Layer 3 communication between

the PCs.

Figure 5 Network diagram

Configuration procedure

1.

Configure the AC:
# Create VLAN 5 and assign GigabitEthernet 1/0/1 to it.

<AC> system-view

[AC] vlan 5

[AC-vlan5] port gigabitethernet 1/0/1

# Create VLAN 10 and assign GigabitEthernet 1/0/2 to it.

[AC-vlan5] vlan 10

Advertising