10 Programming: Q Parameters

166

1

0.6 Chec

king and Changing Q P

a

ra

met

ers

Abbreviations used:
IF

If

EQU

Equals

NE

Not equal

GT

Greater than

LT

Less than

GOTO

Go to

10.6 Checking and Changing

Q Parameters

During a program run or test run, you can check or change Q
parameters if necessary.

ú

If you are in a program run, interrupt it (for example by pressing the
machine STOP button and the STOP soft key). If you are doing a
test run, interrupt it.

ú

To call the Q parameter table, press the
PARAMETER TABLE soft key.

ú

Using the arrow keys you can select a Q-parameter
on the current screen page. You can go to the next
or the previous screen page using the PAGE soft
keys.

ú

If you wish to change the value of a parameter,
enter a new value, confirm it with the ENT key and
conclude your entry with the END key.

To leave the value unchanged, terminate the dialog
with the END key.