12 3-D Touch Probes

210

To measure the angle between two workpiece sides:

ú

Select the probing function by pressing the PROBING ROT soft
key.

ú

Rotation angle: If you will need the current basic rotation later,
write down the value that appears under Rotation
angle.

ú

Make a basic rotation for the first side (see “Compensating
workpiece misalignment”).

ú

Probe the second side as for a basic rotation, but do

not set the

Rotation angle to zero!

ú

Press the PROBING ROT soft key to display the angle PA between
the two sides as the Rotation angle.

ú

Cancel the basic rotation, or restore the previous basic rotation by
setting the Rotation angle to the value that you wrote down
previously.

12.3 Measur

ing W

o

rkpieces with a 3-D

Touc

h

P

robe

PA