D touch probes, Tnc displays,tnc editor, Tnc displays, tnc editor – HEIDENHAIN TNC 310 (286 140) User Manual

Page 234

Advertising
background image

14 Tables and Overviews

222

14.1 Gener

al User P

ar

a

met

ers

14.1 Gener

al User P

ar

a

met

ers

3-D Touch Probes

Probing feed rate for triggering touch probes

MP6120
8

0 to 3000 [mm/min]

Maximum traverse to first probe point

MP6130
0.001
to 30 000 [mm]

Safety clearance to probing point during automatic measurement

MP6140
0.001
to 30 000 [mm]

Rapid traverse for triggering touch probes

MP6150
1
to 30 000 [mm/min]

Measure center misalignment of the stylus when calibrating a triggering touch probe

MP6160
No 180° rotation of the 3-D touch probe during calibration: 0
M function for 180° rotation of the touch probe during
calibration: 1 to 88

TNC displays, TNC editor

Programming station

MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2

Acknowledgment of POWER INTERRUPTED after switch-on

MP7212
Acknowledge with key: 0
Acknowledge automatically: 1

Dialog language

MP7230
German: 0
English: 1

Configure tool tables

MP7260
Inactive: 0
Number of tools per tool table: 1 to 254