12 3-D Touch Probes

202

12.1 Touch Probe Cycles in the Manual

Operation Mode

The TNC must be specially prepared by the machine tool
builder for the use of a 3-D touch probe.

After you press the NC START button, the touch probe approaches
the workpiece in a paraxial movement in the selected probe
function. The machine tool builder sets the probe feed rate (see
figure at right). When the probe contacts the workpiece, it

transmits a signal to the TNC: the coordinates of the probed
position are stored,

stops moving, and

returns to its starting position in rapid traverse.

If the stylus is not deflected within a defined distance, the TNC
displays an error message (MP 6130).

Select the touch probe function

ú

Select the Manual Operation mode.

ú

To choose the touch probe functions, press the
TOUCH PROBE
soft key (2nd soft-key row). The TNC displays
additional soft keys — see table at right.

Function

Soft key

Calibrate the effective length
(2nd soft-key row)

Calibrate the effective radius
(2nd soft-key row)

Basic rotation

Datum setting

Set the datum at a corner

Set the datum at a circle center

12.1 T