Freq Count

Figure 2-25 Frequency Counter Measurement

1. State

Turn on or off the frequency counter.

Key Points:
If no active marker currently exists, turning on the frequency counter will

open a Normal marker automatically.

The frequency readout is more accurate when the frequency counter is

enabled.

The frequency counter measures the frequency near the center

frequency in Zero span mode.


2. Resolution

Set the resolution of the frequency counter manually or automatically. The
available resolutions are 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz and 100 kHz.

Table 2-57 Resolution of frequency counter

Parameter

Explanation

Default

1 kHz

Range

1 Hz to 100 kHz

Unit

GHz, MHz, kHz, Hz

Knob Step

10 times

Direction Key Step 10 times

Counter Readings