of each point on the trace.

2. Max Hold

Display the maximum from multiple sweeps for each point of the trace and
update the data if a new maximum is generated in successive sweeps.

3. Min Hold

Display the minimum from multiple sweeps for each point of the trace and
update the data if a new minimum is generated in successive sweeps.

4. Video Avg

Display the logarithmic average of data from multiple sweeps for each point of
the trace. Traces in this type are smoother.

5. Power Avg

Display the average of data from multiple sweeps of each point of the trace.
Traces in this type are smoother.

6. Freeze

Stop updating the trace data to observe the trace and read the measurement
data. This type is generally used by traces loaded from storage devices or
remote interface as default.

7. Blank

Disable the trace display and all measurements of this trace.

Average Times


Set the number of averages of the selected trace.

Key Points:
 More averages can reduce the noise and the influence of other random signals;

thus highlighting the stable signal characteristics. The larger the number of
averages is, the smoother the trace will be.

 You can use the numeric keys to modify this parameter. Please refer to

Parameter Setting for more details.