Chapter 5 Specifications

RIGOL

User’s Guide for DSA800 Series

5-7

Level Display
Logarithmic level axis

1 dB to 200 dB

Linear level axis

0 to reference level

Number of display points 601
Number of traces

3 + math trace

Trace detectors

normal, positive-peak, negative-peak, sample, RMS,
voltage average
quasi-peak (with EMI-DSA800 option)

Trace functions

clear write, max hold, min hold, average, view, blank

Units of level axis

dBm, dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W

Frequency Response

DSA815

DSA832

DSA875

Frequency response

f

c

≥ 100 kHz, attenuation = 10 dB, relative to 50 MHz,

20℃ to 30℃

PA
off

100 kHz to 1.5 GHz <0.7 dB

<0.5 dB, <0.3 dB (typ.)

1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz

<0.7 dB, <0.3 dB (typ.)

f

c

≥ 1MHz, attenuation = 10 dB, relative to 50 MHz,

20℃ to 30℃

PA
on

100 kHz to 1.5 GHz <1.0 dB

<0.7 dB, <0.3 dB (typ.)

1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz

<0.9 dB, <0.3 dB (typ.)

Input Attenuation Switching Uncertainty

DSA815

DSA832

DSA875

Setting range

0 dB to 30 dB, in 1 dB step

Switching uncertainty

f

c

= 50 MHz, relative to 10 dB, 20℃ to 30℃

<0.5 dB

<0.3 dB

Absolute Amplitude Uncertainty

DSA815

DSA832

DSA875


Uncertainty

f

c

= 50 MHz, peak detector, preamplifier off,

attenuation = 10 dB, input signal level = -10dBm, 20℃
to 30℃
<0.4 dB

<0.3 dB