A.2.3 warning messages – FUJITSU Disk Storage System DX60 User Manual

Page 102

Advertising
background image

Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

102

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

A.2.3

Warning Messages

This section describes the messages that are sent when the severity is Warning.

Warning message list

The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

(*1)

Lower: Description

J 01SSMM00 5

0100MM00 0xww

Controller Module#m(zz xxHz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>

These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.

CM error other than above is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version

J 06SSMM00 5

0600MM00 0x00

Controller Module#m(zz xxHz) BE Expander
Warning <pppppppppppp ssssssssss rrrrr>

CM BE Expander error is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

J 08SSMM0p 5

0800MM0p 0x00

Controller Module#m(zz xxHz) DI Port#p Warning
<pppppppppppp ssssssssss rrrrr>

CM DI Port error is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

Advertising