Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

102

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

A.2.3

Warning Messages

This section describes the messages that are sent when the severity is Warning.

■

Warning message list

The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

(*1)

Lower: Description

J 01SSMM00 5

0100MM00 0xww

Controller Module#m(zz xxHz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>

These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.

CM error other than above is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version

J 06SSMM00 5

0600MM00 0x00

Controller Module#m(zz xxHz) BE Expander
Warning <pppppppppppp ssssssssss rrrrr>

CM BE Expander error is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

J 08SSMM0p 5

0800MM0p 0x00

Controller Module#m(zz xxHz) DI Port#p Warning
<pppppppppppp ssssssssss rrrrr>

CM DI Port error is detected.

SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version