FUJITSU Disk Storage System DX60 User Manual

Page 118

Advertising
background image

Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

118

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

06

FB

80

SMART is reported from the 3.5 inch SAS Disk.

These sense codes are notified when
"Disk reported a Warning" is enabled
for Warning Level in the event
notification setting.
They are not notified during
maintenance operations.

06

FB

81

SMART is reported from the 2.5 inch SAS Disk.

06

FB

90

DE Expander error is detected.

These sense codes are notified when
"Module reported a Warning" is
enabled for Warning Severity Level in
Setup Event Notification.
They are not notified during
maintenance operations.

06

FB

91

DE Expander Port error is detected.

06

FB

0B

Many correctable errors occurred in the CM memory.

06

FB

D2

PSU error is detected.

06

FB

DA

DE exhaust temperature error (Warning) is detected.

06

FB

DB

DE intake temperature error (Warning) is detected.

06

C1

01

CM is rebooted

Sense code

Description

Remarks

SK

ASC

ASCQ

Advertising