Chapter 2 Standard Operations
2.1 Powering On and Off

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

34

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

3

Check that all enclosure's POWER LED and READY LED are lit up.

End of procedure

2.1.3

Powering Off

This section explains how to turn off the ETERNUS DX Disk storage system.

There are two ways to turn the power off:

Via the Power switch
Press the Power switch to turn off the ETERNUS DX Disk storage system.

Via the power synchronized unit
Use the power synchronized unit to turn off the ETERNUS DX Disk storage system.

This section explains how to use the Power switch to turn off the ETERNUS DX Disk storage
system. For other procedures, refer to the related manuals.

Controller enclosure

Drive enclosure

LED for drive enclosure

LED for controller enclosure

IMPORTANT

When turning off the ETERNUS DX Disk storage system, the power
shuts off after the data in the cache memory is written to the disk.
Therefore, it may take one minute (maximum six minutes) for the power
supply to be completely turned off.

Do not turn off the power of the device or network devices that connect
the ETERNUS DX Disk storage system and server while the server is
operating. Turning the power off may result in the loss of data or prevent
data from being saved.

When using a power synchronized unit for power control, make sure to
turn off the power with the server. Even if the ETERNUS DX Disk
storage system is turned off by using the Power switch, the power
synchronization function automatically turns on the power.