A.2.2 error messages – FUJITSU Disk Storage System DX60 User Manual

Page 94

Advertising
background image

Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

94

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

A.2.2

Error Messages

This section describes the messages that are sent when the severity is Error for each type of
event.

Error message list

When the event type is "P"

The following messages are sent when components fail or degrade or when a temperature
error is detected.

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

Trap

Sensor

Info

Lower: Description

P 01SSMM00 2

0100MM00

-

Controller Module#m(zz xxHz) Fault
<pppppppppppp ssssssssss rrrrr>

These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.

CM is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

P 06SSMM00 2

0600MM00

-

Controller Module#m(zz xxHz) BE Expander
Fault <pppppppppppp ssssssssss rrrrr>

CM EXP is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

P 08SSMM0p 2

0800MM0p

-

Controller Module#m(zz xxHz) DI Port#p Fault
<pppppppppppp ssssssssss rrrrr>

CM DI Port is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version