A.2.2 error messages – FUJITSU Disk Storage System DX60 User Manual

Page 94

Advertising
background image

Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

94

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

A.2.2

Error Messages

This section describes the messages that are sent when the severity is Error for each type of
event.

■

Error message list

●

When the event type is "P"

The following messages are sent when components fail or degrade or when a temperature
error is detected.

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

Trap

Sensor

Info

Lower: Description

P 01SSMM00 2

0100MM00

-

Controller Module#m(zz xxHz) Fault
<pppppppppppp ssssssssss rrrrr>

These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.

CM is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

P 06SSMM00 2

0600MM00

-

Controller Module#m(zz xxHz) BE Expander
Fault <pppppppppppp ssssssssss rrrrr>

CM EXP is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

P 08SSMM0p 2

0800MM0p

-

Controller Module#m(zz xxHz) DI Port#p Fault
<pppppppppppp ssssssssss rrrrr>

CM DI Port is disconnected.

SS: Component subtype
MM
: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

Advertising