FUJITSU Disk Storage System DX60 User Manual

Page 97

Advertising
background image

Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

97

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

P 13SSMM0p 2

1300MM0p

-

Controller Module#m(zz xxHz) FE Expander
Port#p Fault <pppppppppppp ssssssssss rrrrr>

These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.

CM FE Expander Port is disconnected.

SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

P 1A00MM0p 2

1A00MM0p

-

FC SFP Controller Module#m Port#p Fault
<pppppppppppppppp ssssssssssssssss rrrr
oooooooo
>

SFP is disconnected.

MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
oo...: Additional information

P 80SSdd0N

2

8000dd0N

-

Disk Drive DE#dd-Disk#n(SAS xxxGB yykrpm
ccccccc) Fault <pppppppppppp ssssssssssss
rrrr
>

These messages
are notified when
"Disk was broken" is
enabled for Error
Severity Level in the
event notification
setting.
They are not notified
during maintenance
operations.

3.5 inch Disk is disconnected.

SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot
spare (Spare))
pp...: Component number
ss...: Serial number
rr...: Version

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

Trap

Sensor

Info

Lower: Description