Appendix A Event Notification Message List
A.2 Message List

ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-

106

Copyright 2012 FUJITSU LIMITED

P3AM-5512-03ENZ0

*1:

This row indicates TrapWarningInfo for Trap No. 5 and TrapSensorInfo for Trap No. 6.

J C3SSMM00 5

0B00MM00 0x00

Controller Module#m(zz xxHz) Cache(MEM)
Correctable Error <pppppppppppppppppp
ssssssssssss rrrrrr>

These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.

Many correctable errors occurred in the CM memory.

SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version

J D200dd0n

5

D200dd0n 0x00

Power Supply Unit DE#dd/PSU#n Warning
<pppppppppppp ssssssssss rrrr>

PSU error is detected.

dd: DE-ID ("00" for a controller enclosure)
n: PSU number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version

J DASSdd00 6

DA00dd00 1

DE Exhaust temperature DE#dd Warning

DE exhaust temperature error (Warning) is detected.

SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)

J DBSSdd00 6

DB00dd00 1

DE Intake temperature DE#dd Warning

DE intake temperature error (Warning) is detected.

SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)

Event type

and event

code

SNMP Trap

Upper: Message

Remarks

Trap

No.

TrapItemID

(*1)

Lower: Description

Advertising