Resolving the transfer cooling error, E 97 – FARGO electronic HDP820 User Manual

Page 111

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

HDP 800 Series Card Printer/Encoders Service Manual (Rev. 5.0)

97

Resolving the Transfer Cooling error

Symptom: The LCD indicates a Transfer Cooling error for an extended period of time.
Driver Settings may be too extreme.

Step Procedure

1

Verify if the Driver settings are too extreme.

a. Run a self-test from the Printer.

b. Select Menu from the LCD.

c. Select Print Test Image from the menu.
d. Select Gray/Align Self test from the Menu. (Note: This will cause the

Laminator to attempt to operate at the default temperature.)

e. If the Transfer Cooling message is not displayed for an extended period of

time, the transfer temperature setting in the LCD is set too high.

2. Adjust

the

Transfer

Temperature

setting

a. Press Menu on the LCD.

b. Select Setup Printer, scroll down, and then select Transfer Temp from the

menu.

c. Reduce the current value by 5.

d. Press OK and exit out of the menu.

e. Run a self-test.

f. If the Transfer Cooling message still appears, repeat steps a through e.

g. If the Transfer Cooling message is not displayed, continue printing.

3

Verify if the Thermocouple has failed.

a. Check the Thermocouple by using a Multimeter to check the leads across

the Thermocouple Control C111 on the Lamination Board. (Note: The
voltage should be equal to the desired temperature (degrees C) divided by
100 with an accuracy of +/- 10 degrees C (e.g., 150 degrees equals
1.5VDC).

b. If the correct value is not retuned, the Thermocouple may need to be

replaced.

4

Verify if the Lamination Board is functioning properly. Replace the Lamination
Board (as needed). See the

Replacing the Lamination Board (140402)

procedure in Section 5, page 368.

Advertising