Section 8: board level diagnostics, Board errors, Resolving the ee memory error – FARGO electronic HDP820 User Manual

Page 273: Resolving the ee checksum error, Resolving the dram, Memory error, Resolving the ee memory, Error, Resolving the ee, Checksum error

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

HDP 800 Series Card Printer/Encoders Service Manual (Rev. 5.0)

438

Section 8: Board Level Diagnostics

The purpose of this section to provide the User with specific Board Level Diagnostic
procedures for Board Errors and Sensor Testing for the HDP 820 Card Printer.

Board Errors

Resolving the EE Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Print Board (A000271)

procedure in Section 5, page 367 for

instructions.

3

As an alternative to replacing the Main Print Board, the chip U16 (080239) may
be replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)

Resolving the EE Checksum Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Print Board (A000271)

procedure in Section 5, page 367.

3

As an alternative to replacing the Main Print Board, the chip U16 (080239) may
be replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)