Resolving the dram memory error, Resolving the ram memory error, Resolving the fpga error – FARGO electronic HDP820 User Manual

Page 274

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

HDP 800 Series Card Printer/Encoders Service Manual (Rev. 5.0)

439

Resolving the DRAM Memory Error

Symptom: An error has occurred in the removable memory Module (SIMM).

Step Procedure

1

Reboot the Printer.

2

If the problem persists, remove the rear cover and ensure that the SIMM
(080229) is seated properly.

3

If the memory Module is not seated properly, remove the Board and reinstall.

4

If the installation appears correct and the error persists, the SIMM (080229) on
the Main Print Board will need to be replaced.

Resolving the RAM Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, replace the Main Print Board. See

Replacing the Main

Print Board (A000271)

procedure in Section 5, page 367.

3

As an alternative to replacing the Main Print Board, the chip U17 (080229) may
be replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)

Resolving the FPGA Error

Symptom: An unexpected hardware error has occurred.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Print Board (A000271)

procedure in Section 5, page 367.

3

As an alternative to replacing the Main Print Board, the chip U2 (080066) may be
replaced. (Note: Fargo recommends that only a qualified electronics technician
perform this procedure.)