Setting the Magnetic TOF

Use this setting to position the magnetic data at the correct distance from the leading edge of
the card.

The Magnetic TOF is the distance from the edge of the card to the Start Sentinel (SS).

The Start Sentinel marks the beginning of the encoded data. (Note: According to the
magnetic recording standard (ISO 7811), the correct Start Sentinel distance is 0.293
inches ± 0.020 inches (7.44 mm ± 0.51 mm) from the leading edge of the card.)

Step Procedure

1

a. Measure this distance by making the data visible using a magnetic viewer or

developer solution.

b. Alternatively, use a magnetic card analyzer to measure the Start Sentinel

distance.

2

a. Use a magnetic viewer or developer solution or spray to make the magnetic

data visible (in order to identify the Start Sentinel as the first set of magnetic
lines or first one-bit, which are visibly closer together than the large number
of evenly spaced lines or leading zero-bits that fill the space to the edge of
the card, as shown on the next page).

b. Use a magnifying device with a built-in measuring scale to measure the

distance from the edge of the card to the Start Sentinel in the data, as shown
on the next page.

3

If the Start Sentinel is too far from the leading edge of the card, reduce (or make
negative) the Magnetic TOF setting needs.

OR

If the Start Sentinel is too close to the leading edge of the card, increase (or
make positive) the Magnetic TOF setting needs.

4

Select MENU, Setup Printer and Magnetic TOF.

5

Adjust the setting by the amount determined by the following formula:

0.293 inches: Represents measured SS distance (inches) x 300 steps per
in.
OR

7.4 mm: Represents measured SS distance (millimeter) x 11.8 steps per
mm.

Example: (0.293 – 0.284) x 300 = 2.7