SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009

3. Loosen the four (4) captive screws at the front of the server (

FIGURE 5-2

).

FIGURE 5-2

Loosening the Captive Screws and Pulling Out the Server

4. Pull the system to the fan stop.

The system automatically locks in place at the fan stop.

5.1.2

Sliding the Server Into the Equipment Rack

1. Push the green plastic releases on each slide rail and push the server back into

the equipment rack.

2. Tighten the four (4) captive screws at the front of the server to secure it in the

rack (

FIGURE 5-2

).

3. Tighten the four (4) captive screws on the shipping brackets at the rear of the

server (

FIGURE 5-1

).

4. Restore the rack antitilt features to their original position.