FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 133

Advertising
background image

Chapter 6

Storage Devices Replacement

6-27

6.3.5

Accessing the Tape Drive Backplane of the SPARC
Enterprise M4000 Server

Caution –

There is an electrical hazard if the power cords are not disconnected. All

power cords must be disconnected to completely remove power from the server.

Caution –

Use proper ESD grounding techniques when handling components. See

“Safety Precautions” on page 1-1

.

1. Power off the server.

This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See

“Powering the

Server Off Using Software” on page 4-12

.

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When drawing out the SPARC Enterprise M4000/M5000 Server to the front,

release the cable tie holding the PCI cables on the rear of the server.

2. Remove the fan cover.

This step includes deploying the rack’s antitilt features (if applicable), sliding the
server out of the equipment rack, removing the 60-mm fan units and removing
the fan cover. See

“Removing the Fan Cover” on page 5-8

.

3. Remove the 60-mm fan backplane.

This step includes removing the cable connectors, loosening the captive screws
and removing the 60-mm fan backplane. See

“Removing the 60-mm Fan

Backplane” on page 10-11

.

Advertising