Removing and Replacing a FRU

1. From the XSCF Shell prompt, type the replacefru command.

CODE EXAMPLE 4-1

replacefru

command

XSCF> replacefru

----------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. FAN (Fan Unit)

2. PSU (Power Supply Unit)

----------------------------------------------------------------

Select [1,2|c:cancel] :1

----------------------------------------------------------------

Maintenance/Replacement Menu

Please select a FAN to be replaced.

No. FRU Status

--- --------------- ------------------

1. FAN_A#0 Faulted

2. FAN_A#1 Normal

3. FAN_A#2 Normal

4. FAN_A#3 Normal

----------------------------------------------------------------

Select [1-4|b:back] :1

You are about to replace FAN_A#0.

Do you want to continue?[r:replace|c:cancel] :r

Please confirm the CHECK LED is blinking.

If this is the case, please replace FAN_A#0.

After replacement has been completed, please select[f:finish] :f