Installing the sparc – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 236

Advertising
background image

13-10

SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009

13.1.7

Installing the SPARC Enterprise M5000
Motherboard Unit

Caution –

The motherboard is heavy. Two people are recommended to lift the unit.

Caution –

Use proper ESD grounding techniques when handling components. See

“Safety Precautions” on page 1-1

.

1. Align the motherboard unit feet with the rails and lower the unit into the

server.

2. Push the motherboard unit handles down until they are horizontal to seat the

board.

3. Tighten the two (2) captive screws in the center of the motherboard unit to

secure the motherboard unit handles in place.

4. Secure the eight (8) bus bar screws at the front of the motherboard unit using a

magnetic screwdriver.

5. Install the two (2) CPU module baffles and secure them with the latches.

Advertising