If fmadm faulty occurs, the FMA resource cache on the OS side can be cleared
without problems; the data in it need not match the hardware failure information
retained on the XSCF side.

2.6.3.2

fmadm config

Command

The fmadm config command output shows you the version numbers of the
diagnosis engines in use by your server, as well as their current state. You can check
these versions against information on the SunSolve web site to determine if you are
running the latest diagnostic engines, as shown in the following example.

2.6.4

Using the fmstat Command

The fmstat command can report statistics associated with the Solaris fault
manager. The fmstat command shows information about DE performance. In the
example below, the fmd-self-diagnosis DE (also seen in the console output) has
received an event which it accepted. A case is “opened” for that event and a
diagnosis is performed to “solve” the cause for the failure. See the following
example.

# fmadm repair

STATE RESOURCE / UUID

-------- --------------------------------------------------------

degraded dev:////pci@1e,600000

0ee65618-2218-4997-c0dc-b5c410ed8ec2

XSCF> fmadm config

MODULE VERSION STATUS DESCRIPTION

eft 1.16 active eft diagnosis engine

event-transport 2.0 active Event Transport Module

faultevent-post 1.0 active Gate Reaction Agent for errhandd

fmd-self-diagnosis 1.0 active Fault Manager Self-Diagnosis

iox_agent 1.0 active IO Box Recovery Agent

reagent 1.1 active Reissue Agent

sysevent-transport 1.0 active SysEvent Transport Agent

syslog-msgs 1.0 active Syslog Messaging Agent

XSCF>