2 using the prtdiag command, 1 options, Using the prtdiag – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 66: Options

Advertising
background image

2-28

SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009

2.7.2

Using the prtdiag Command

The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.

The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.

Note –

The prtdiag command might indicate a slot number different than that

identified elsewhere in this document. This is normal.

2.7.2.1

Options

TABLE 2-13

describes options for the prtdiag command and how those options can

help troubleshooting.

TABLE 2-13

Options for

prtdiag

Option

Description

How It Can Help

No option

Lists components.

Identifies CPU timing and PCI cards installed.

-v

Verbose mode. Displays the
time of the most recent AC
power failure and the most
recent hardware fatal error
information.

Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.

Advertising