Chapter 8

I/O Unit Replacement

8-7

Note –

When you insert the PCI cassette using hot-swap, the cassette is

automatically powered on and configured. Check that the POWER LED on the
cassette is lit to be certain the cassette is correctly seated.

3. Connect all cables to the PCI cassette and reconnect the cable management arm

if necessary.

8.1.4

Securing the Server

1. Add the PCI cassette to the system.

This step includes using the cfgadm command to connect and confirm the PCI
cassette has been added to the system. See

“Adding a FRU Into a Domain” on

page 4-5

.

2. Verify the state of the status LEDs on the PCI cassette.

The green POWER LED should be On and the CHECK LED should not be On.

8.2

PCI Card Replacement

The PCI card mounts in the PCI cassette.

8.2.1

Removing the PCI Card

1. Remove the PCI cassette containing the PCI card from the server.

See

“Removing the PCI Cassette” on page 8-5

.

2. Open the cassette lever until it is horizontal (

FIGURE 8-5

).

3. Loosen the three (3) captive screws on the adjustable stops with a screwdriver

and move the adjustable stops away from the PCI card.

4. Remove the PCI card from the cassette and place it on the ESD mat.