FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 161

Advertising
background image

Chapter 8

I/O Unit Replacement

8-17

Note –

Do not pull the retention clips of the DC-DC converter retainer too far out

when disengaging the DC-DC converter. This might cause the DC-DC converter
retainer retention clips to deform and prevent proper seating of the DC-DC
converter.

b. G

ently pull the DC-DC converter from the slot.

c. Place

the DC-DC converter on the ESD mat.

8.4.3

Installing the I/O Unit DC-DC Converter
(DDC_A #0 or DDC_B #0)

Caution –

The DC-DC converter (DDC_B#0) that goes in the slot on the DC-DC

Converter Riser has a metal heat sink. The DC-DC converter (DDC_A#0) that goes in
the slot on the I/O board does not. If these converters are installed in the wrong
slots, serious damage to the I/O unit will result.

Determine if your server currently has a label installed on the I/O unit DC-DC
converter (DDC_B#0).

FIGURE 8-11

DC-DC Converter

(DDC_B#0)

Label

If your server does not have a label covering part of the I/O unit DC-DC
converter and has no DC-DC converter retainer, go to

Step 1

(

FIGURE 8-12

).