2 monitoring output, 3 messaging output, Monitoring output – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 55: Messaging output

Advertising
background image

Chapter 2

Fault Isolation

2-17

2.4.2

Monitoring Output

To understand error conditions, collect the monitoring output information. For the
collection of the information, use the commands shown in

TABLE 2-8

.

2.4.3

Messaging Output

To understand error conditions, collect messaging output information, use the
commands shown in

TABLE 2-9

.

Each error message logged by the predictive self-healing architecture has a code
associated with it as well as a web address that can be followed to get the most up-
to-date course of action for dealing with that error.

Refer to the Solaris 10 documentation for more information on predictive self-
healing.

TABLE 2-8

Commands for Checking the Monitoring Output

Command

Operand

Description

showlogs(8)

console

Displays console of Domain.

monitor

Logs messages that are displayed in the message window.

panic

Logs output to the console during a panic.

ipl

Collects console data generated during the period of the
power on of a domain to the completion of the operating
system start.

TABLE 2-9

Commands for Checking the Messaging Output

Command

Operand

Description

showlogs

env

Displays the temperature history log. The environmental
temperature data and power status are indicated in 10-minute
intervals. the data is stored for a maximum of six months.

power

Displays the power and reset information.

event

Displays information reported to the operating system and
stored as event logs.

error

Displays error logs.

fmdump(1M)

fmdump(8)

Displays fault management architecture diagnostic results and
errors. It is provided as a Solaris command and XSCF Shell
command.

Advertising