2 fmdump -e command, 3 using the fmadm faulty command, 1 fmadm repair command – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 61: Using the fmadm faulty

Advertising
background image

Chapter 2

Fault Isolation

2-23

2.6.2.2

fmdump -e

Command

To get information of the errors that caused this failure you can use the -e option,
as shown in the following example.

2.6.3

Using the fmadm faulty Command

The fmadm faulty command can be used by administrators and service personnel
to view and modify system configuration parameters that are maintained by the
Solaris fault manager. The command is primarily used to determine the status of a
component involved in a fault, as shown in the following example.

The PCI device is degraded and is associated with the same UUID as seen above.
You might also see “faulted” states.

2.6.3.1

fmadm repair

Command

If fmadm faulty occurs, the faulty FRU (CPU, memory, or I/O unit) is replaced,
and then the fmadm repair command needs to be executed to clear FRU
information on the domain. If the fmadam repair command is not executed, error
messages continue to be output.

XSCF> fmdump -e

TIME CLASS

Oct 03 13:52:48.9532 ereport.fm.fmd.module

Oct 03 13:52:48.9610 ereport.fm.fmd.module

Oct 03 13:52:48.9674 ereport.fm.fmd.module

Oct 03 13:52:48.9738 ereport.fm.fmd.module

# fmadm faulty

STATE RESOURCE / UUID

-------- --------------------------------------------------------

degraded dev:////pci@1e,600000

0ee65618-2218-4997-c0dc-b5c410ed8ec2

# fmadm repair

0ee65618-2218-4997-c0dc-b5c410ed8ec2