C-2

SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009

TABLE C-1

identifies the FRU components.

Note –

If the hard disk drive is the boot device, the hard disk will have to be

replaced using cold replacement procedures. However, active replacement can be
used if the boot disk can be isolated from the Solaris OS by disk mirroring software
or other software. The procedure for isolating the hard disk drive from the Solaris
OS varies depending on whether disk mirroring software or other support software
is used. For details, see the relevant software manuals.

TABLE C-1

Midrange Server

FRU Components

Component

Redundant

Cold
Replacement

Hot
Replacement

Active
Replacement

Motherboard unit

No

Yes

Motherboard DC-DC Converter

No

Yes

CPU module

No

Yes

Memory board

Yes

Yes

DIMM No

Yes

eXtended System Control facility unit

No

Yes

I/O unit

No

Yes

I/O DC-DC Converter

No

Yes

I/O DC-DC Converter Riser

No

Yes

PCI cassette

No

Yes

Yes

Yes

Fan Yes

Yes

Yes

Yes

Fan backplane

No

Yes

Power supply unit

Yes

Yes

Yes

Yes

Busbar/I/O backplane/power backplane
(SPARC Enterprise M5000)

No

Yes

I/O backplane/power backplane (SPARC
Enterprise M4000)

No

Yes

Hard disk drive

Yes

Yes

Yes

Yes

Tape drive unit (optional)

No

Yes

Yes

Yes

CD-RW/DVD-RW Drive Unit (DVDU)

No

Yes

Yes

Operator panel

No

Yes