1 checking the software configuration, 2 checking the firmware configuration, Checking the software configuration – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 45: Checking the firmware configuration

Advertising
background image

Chapter 2

Fault Isolation

2-7

2.2.2.1

Checking the Software Configuration

The following procedure for these checks can be made from the domain console:

1. Type showrev.

The showrev

command prints the system configuration information to the

screen.

2.2.2.2

Checking the Firmware Configuration

Login authority is required to check the firmware configuration. The following
procedure for these checks can be made from the maintenance terminal:

1. Log in with the account of the XSCF hardware maintenance engineer.

2. Type version(8).

The version(8)

command prints the firmware version information to the

screen. See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide
for more detailed information.

showboards(8)

XSCF Shell command that indicates information on eXtended system
board (XSB). It can indicate information on XSB that belongs to the
specified domain and information on all XSBs mounted. The
eXtended System Board (XSB) combines the hardware resources of a
physical system board. The SPARC Enterprise servers can generate
one (Uni-XSB) or four (Quad-XSB) XSB(s) from one physical system
board.

showdcl(8)

XSCF Shell command that displays the configuration information of a
domain (hardware resource information).

showfru(8)

XSCF Shell command that displays the setting information of a
device.

# showrev

XSCF> version(8)

TABLE 2-2

Commands for Checking Software and Firmware Configuration (Continued)

Command

Description

Advertising