2 top cover remove and replace, 1 removing the top cover, Top cover remove and replace – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 101: Removing the top cover

Advertising
background image

Chapter 5

Internal Components Access

5-5

5.2

Top Cover Remove and Replace

You must slide the server out of the equipment rack before removing the top cover.

5.2.1

Removing the Top Cover

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When drawing out the SPARC Enterprise M4000/M5000 Server to the front,

release the cable tie holding the PCI cables on the rear of the server.

Caution –

Use proper ESD grounding techniques when handling components. See

“Safety Precautions” on page 1-1

.

1. Deploy the rack’s antitilt features (if applicable).

Refer to the rack manual for details on the rack’s antitilt features.

2. Loosen the four (4) captive screws at the front of the server (

FIGURE 5-2

).

3. Loosen the four (4) captive screws on the shipping brackets at the rear of the

system (

FIGURE 5-1

).

Note –

During installation the power cables should have been bundled into a loop

with enough slack to allow the system to slide out on the rails. This is called the
service loop. If this is not the case the power cables will have to be disconnected to
allow the server to pull all the way out of the equipment rack.

4. Pull the server to the fan stop.

The server automatically locks in place at the fan stop.

5. Push the green plastic releases on each slide rail and pull the server until it is

fully extended.

The server automatically locks in place when fully extended.