6 removing the i/o unit dc-dc converter riser, Removing the i/o unit dc-dc converter riser – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 166

Advertising
background image

8-22

SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009

8.4.6

Removing the I/O Unit DC-DC Converter Riser

1. Loosen the two screws at the front of the I/O unit using a No. 2 screwdriver

(

FIGURE 8-14

).

2. Push the I/O unit cover slightly forward and then pull the front of the cover up

to remove the cover from the I/O unit.

3. Loosen the three screws that hold the metal bracket in place and tilt the

bracket towards the front of the I/O unit to expose the inside of the I/O unit.

The bracket has a circuit board and cable connected to it. It is not necessary to
remove the entire bracket.

4. Pull the DC-DC converter riser from the socket (

FIGURE 8-14

).

Determine if your server currently has a label installed on the I/O unit DC-DC
converter (DDC_B#0).

If your server does not have a label covering part of the I/O unit DC-DC
converter, go to

Step 5

.

If your server does have a label covering part of the I/O unit DC-DC converter,
start from one corner of the label and peel the label free of the I/O unit DC-DC
converter.

5. Disengage the DC-DC converter from the slot in the DC-DC converter riser or

DC-DC converter retainer and place them both on the ESD mat.