Chapter 4

FRU Replacement Preparation

4-5

Note –

For a PCI cassette, type the cfgadm -c disconnect command to

disconnect the component from the domain.

The Ap_Id is shown in the output of cfgadm.

iou#0-pci#0

for example.

3. Type the cfgadm command to confirm the component is now disconnected.

4.2.2

Removing and Replacing a FRU

Once the FRU has been removed from the domain, see

“Removing and Replacing a

FRU” on page 4-7

4.2.3

Adding a FRU Into a Domain

1. From the Solaris prompt, type the cfgadm command to connect the component

to the domain.

The Ap_Id is shown in the output of cfgadm.

iou#0-pci#0

for example.

2. Type the cfgadm command to confirm the component is now connected.

# cfgadm -a

Ap_Id Type Receptacle Occupant

Condition

iou#0-pci#0 etherne/hp disconnected unconfigured

unknown

iou#0-pci#1 fibre/hp connected configured ok

iou#0-pci#2 pci-pci/hp connected configured ok

# cfgadm -c configure

Ap_Id

# cfgadm -a

Ap_Id Type Receptacle Occupant

Condition

iou#0-pci#0 etherne/hp connected configured ok

iou#0-pci#1 fibre/hp connected configured ok

iou#0-pci#2 pci-pci/hp connected configured ok