5 verifying hardware operation, Verifying hardware operation – FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 93

Advertising
background image

Chapter 4

FRU Replacement Preparation

4-15

4.4.5

Verifying Hardware Operation

1. From the ok prompt, press the Enter key, and press the “#.” (number sign and

period) keys to switch you from the domain console to the XSCF console.

2. Type the showhardconf command to confirm the new component is installed.

CODE EXAMPLE 4-6

showhardconf

XSCF> showhardconf

SPARC Enterprise 5000;

+ Serial:BE80601000; Operator_Panel_Switch:Service;

+ Power_Supply_System:Single; SCF-ID:XSCF#0;

+ System_Power:On;

Domain#0 Domain_Status:Powered Off;

MBU_B Status:Normal; Ver:0101h; Serial:78670002978: ;

+ FRU-Part-Number:CF00541-0478 01 /541-0478-01 ;

+ Memory_Size:64 GB;

CPUM#0-CHIP#0 Status:Normal; Ver:0201h; Serial:PP0629L068 ;

+ FRU-Part-Number:CF00375-3477 50 /375-3477-50 ;

+ Freq:2.150 GHz; Type:16;

+ Core:2; Strand:2;

CPUM#0-CHIP#1 Status:Normal; Ver:0201h; Serial:PP0629L068 ;

+ FRU-Part-Number:CF00375-3477 50 /375-3477-500 ;

+ Freq:2.150 GHz; Type:16;

+ Core:2; Strand:2;

MEMB#0 Status:Normal; Ver:0101h; Serial:01068: ;

+ FRU-Part-Number:CF00541-0545 01 /541-0545-01 ;

MEM#0A Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123520;

+ Type:1B; Size:1 GB;

MEM#0B Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123e25;

+ Type:1B; Size:1 GB;

MEM#1A Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123722;

+ Type:1B; Size:1 GB;

MEM#1B Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123b25;

+ Type:1B; Size:1 GB;

MEM#2A Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123e20;

+ Type:1B; Size:1 GB;

MEM#2B Status:Normal;

+ Code:c1000000000000004572T128000HR3.7A 252b-04123822;

+ Type:1B; Size:1 GB;

Advertising