Setdualpowerfeed – FUJITSU SPARC ENTERPRISE M4000 User Manual

Page 179

Advertising
background image

setdualpowerfeed(8)

System Administration

189

NAME

setdualpowerfeed - set dual power feed mode

SYNOPSIS

setdualpowerfeed -s

key

setdualpowerfeed -h

DESCRIPTION

The setdualpowerfeed(8) command specifies dual power feed mode in the
system.

The setdualpowerfeed(8) command is valid in a midrange server only. In a high-
end server, when the power cabinet for dual power feed connected, it automatically
configures the dual power feed mode.

Any change made in dual power feed mode becomes valid when circuit breaker to
the system is turned on. Before rebooting the system, a message that dual power
feed mode was changed is displayed.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXTENDED

DESCRIPTION

The state of the current dual power feed mode can be checked by using the
showdualpowerfeed

(8) command.

EXAMPLES

EXAMPLE 1

Disables dual power feed mode in the system. Before rebooting the sys-
tem, a message is displayed.

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-s

key

Sets dual power feed mode in the system. Either of the following
can be specified for key:

enable

Enables the dual power feed mode.

disable

Disables dual power feed mode.

XSCF>

setdualpowerfeed -s disable

enable -> disable
NOTE: Dual power feed will be disabled the next time the platform is
powered on.