Ioxadm – FUJITSU SPARC ENTERPRISE M4000 User Manual

Page 93

Advertising
background image

ioxadm(8)

System Administration

85

NAME

ioxadm - manage External I/O Expansion Units

SYNOPSIS

ioxadm

[-f] [-p] [-v] [-M] env [-e] [-l] [-t] [ target [ sensors]]

ioxadm

[-f] [-p] [-v] [-M] list [ target]

ioxadm

[-f] [-p] [-v] [-M] locator [on|off] [ target]

ioxadm

[-f] [-p] [-v] [-M] poweroff target

ioxadm

[-f] [-p] [-v] [-M] poweron target

ioxadm

[-f] [-p] [-v] [-M] reset target

ioxadm

[-f] [-p] [-v] [-M] setled [ on|off|slow|fast] target led_type

ioxadm -h

DESCRIPTION

ioxadm

(8) manages External I/O Expansion Units and link cards attached to the

system.

For this utility, an operand with parameters and a target device must both be
specified. The target device can be a downlink card mounted in a built-in PCI slot
in the host system; an External I/O Expansion Unit; or a field replaceable unit
(FRU) in an External I/O Expansion Unit. The downlink card is identified by a
string which identifies the host path to the card. An uplink card is a FRU in the
I/O boat.

Privileges

You must have one of the following privileges to run these commands:

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported.

Required Privileges

Operands

platop

env

, list

platadm

env

, list, locator, poweroff, poweron

fieldeng

All operands

-f

Forces command execution by ignoring warnings.

-h

Displays usage statement.

When used with other options or operands, an error occurs.

Advertising