background image

showboards(8)

320

XSCF Reference Manual • Last Revised January 2007

EXAMPLE 2

Displays detailed information on all mounted system boards.

EXAMPLE 3

Displays information on XSB#00-0.

EXAMPLE 4

Displays detailed information on XSB#00-0.

EXAMPLE 5

Displays system boards located in the system board pool.

EXAMPLE 6

Displays the system boards that are defined for domain ID 0 and located in
the system board pool.

EXIT STATUS

The following exit values are returned:

SEE ALSO

addboard(8)

, addcodlicense(8), deleteboard(8), deletecodlicense(8),

moveboard(8)

, setdcl(8), setupfru(8), showcodlicense(8), showcodusage(8),

showdcl(8)

, showdevices(8), showfru(8)

XSCF>

showboards -v -a

XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ---
00-0 00(00) Assigned y y y Passed Normal n
00-1 * 00(01) Assigned y y y Passed Normal n
00-2 SP Available y n n Passed Normal n
00-3 02(00) Unavailable y n n Unknown Normal n

XSCF>

showboards 00-0

XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 15(00) Assigned

y y y Passed Normal

XSCF>

showboards -v 00-0

XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ---
00-0 * 15(00) Assigned

y n n Passed Normal y

XSCF>

showboards -a -c sp

XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 SP Available y n n Passed Normal
00-2 SP Available y n n Passed Normal
00-3 SP Available y n n Passed Normal

XSCF>

showboards -d 0 -c sp

XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-2 SP Available y n n Passed Normal

0

Successful completion.

>0

An error occurred.