FUJITSU SPARC ENTERPRISE M4000 User Manual

Page 425

Advertising
background image

testsb(8)

System Administration

499

mounted.

EXIT STATUS

The following exit values are returned:

SEE ALSO

addfru(8)

, deletefru(8), replacefru(8), setupfru(8), showboards(8),

showfru(8)

XSCF>

testsb -c all

Initial diagnosis is about to start. Continue? [y|n] :

y

Ignore warmup-time and air-conditioner-wait-time, Continue?[y|n] :

y

SB power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB Test Fault
---- ------- --------
00-0 Passed Normal
01-0 Passed Normal
02-0 Passed Normal
03-0 Passed Normal

0

Successful completion.

>0

An error occurred.