showenvironment(8)

System Administration

293

NAME

showenvironment - display the intake air temperature and humidity, temperature
sensor information, voltage sensor information, and fan rotation information about
the system

SYNOPSIS

showenvironment

[-M] [ type]

showenvironment -h

DESCRIPTION

showenvironment

(8) command displays the information listed below.

The following types of the information are displayed:

Privileges

You must have one of the following privileges to run this command:

useradm

, platadm, platop, fieldeng

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

OPERANDS

The following operand is supported:

Environment
information

Intake temperature and humidity of the system (humidity only
for high-end server)

Temperature
information

Intake temperature of the system and exhaust temperature of
each component

Voltage
information

Voltage sensor value

Fan rotation
information

Fan rotational state and revolutions per unit of time

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-M

Displays text by page. This option provides a function that is
the same as that of the more command.

type

Specifies the one of the type of information to be displayed. The
following types can be specified. If this type setting is omitted,
intake temperature and humidity information about the system
is displayed:
temp

Displays temperature information.

volt

Displays voltage information.

Fan

Displays fan rotation information.