FUJITSU SPARC ENTERPRISE M4000 User Manual

Page 424

Advertising
background image

testsb(8)

498

XSCF Reference Manual • Last Revised January 2007

EXAMPLES

EXAMPLE 1

Performs the initial diagnosis on PSB#00.

EXAMPLE 2

Performs an initial diagnosis of PSB#01 with detailed messages displayed.

EXAMPLE 3

Performs the initial diagnosis on all the PSB that are mounted.

EXAMPLE 4

Ignores the settings for the warm-up time of the system and the wait time
before system startup to perform the initial diagnosis on the PSB that are

XSCF>

testsb 0

Initial diagnosis is about to start, Continue?[y|n] :

y

SB#00 power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB Test Fault
---- ------- --------
00-0 Passed Normal
00-1 Passed Normal
00-2 Passed Normal
00-3 Passed Normal

XSCF>

testsb -v 1

Initial diagnosis is about to start. Continue? [y|n] :

y

SB#01 powered on sequence started.

:
:

Initial diagnosis has completed.
{0} ok SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB Test Fault
---- ------- --------
01-0 Passed Normal

XSCF>

testsb -c all

Initial diagnosis is about to start. Continue? [y|n] :

y

SB power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB Test Fault
---- ------- --------
00-0 Passed Normal
01-0 Passed Normal
02-0 Passed Normal
03-0 Passed Normal

Advertising