Showdualpowerfeed – FUJITSU SPARC ENTERPRISE M4000 User Manual

Page 319

Advertising
background image

showdualpowerfeed(8)

System Administration

373

NAME

showdualpowerfeed - display the current setting of dual power feed mode

SYNOPSIS

showdualpowerfeed

showdualpowerfeed -h

DESCRIPTION

The showdualpowerfeed(8) command displays the current setting of dual power
feed mode in the system.

The showdualpowerfeed(8) command is valid in a midrange server only.

The dual power feed mode can be set by the setdualpowerfeed(8) command.
Also, before the dual power feed mode is changed by the setdualpowerfeed(8)
command, the values of changed settings are displayed.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXAMPLES

EXAMPLE 1

Displays the current setting of dual power feed mode in the system.

EXAMPLE 2

Changes the dual power feed mode with the setdualpowerfeed(8) com-
mand and then displays the current state.

EXIT STATUS

The following exit values are returned:

SEE ALSO

setdualpowerfeed(8)

-h

Displays usage statement.

XSCF>

showdualpowerfeed

Dual power feed is enabled.

XSCF>

showdualpowerfeed

enable -> disable
NOTE: Dual power feed will be disabled the next time the platform is
powered on.

0

Successful completion.

>0

An error occurred.