cfgdevice(8)

28

XSCF Reference Manual • Last Revised June 2007

The current status of the drive that is displayed with this command includes the
following types of status information:

The cfgdevice(8) command is valid only for high-end server.

Privileges

You must have one of the following privileges to run this command:

For connection and disconnection:

platadm

, fieldeng

For displaying the status:

platadm

, fieldeng

Refer to setprivileges(8) for more information.

port_no

Port number of the port where the IOUA is installed and that
can be connected to the DVD drive/tape drive unit. It is
displayed in the "IOU number-PCI slot number" format.

IOU/SAS-status

Connection status between IOUA and built-in switching unit.
It is changed by specifying "attach" or "detach."

enable/disable

: Setting status of the cfgdeive(8)

command

enable

: Connected with "-c attach."

disable

: Not connected.

up/down

: Logical connection between IOUA and built-in

switching unit.

up

: Connected.

down

: Not connected.

SAS-status

Connection status between I/O unit and the system.

enable/disable

: Connection setting between I/O unit

and the system. When starting a domain with no I/O unit,
the "disable" may be displayed.

enable

: Yes

disable

: No

up/down

: Logical connection between I/O unit and the

system.

up

: Connected.

down

: Not connected.