English – Middleby Marshall PS310 User Manual

Page 6

Advertising
background image

ENGLISH

6

SECTION 2 - INSTALLATION

WARNING

Keep the appliance area free and clear of combustibles.

WARNING

Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no

obstructions around or underneath the oven. Constructional changes to the area where the oven is

installed shall not affect the air supply to the oven.

CAUTION

For additional installation information, refer to the following documents:

PS360 Pre-Installation Procedures Manual (Middleby Marshall P/N 88210-0024)

PS360 Installation Manual (Middleby Marshall P/N 88210-0025)

Or, contact your local Authorized Service Agent.

NOTE

There must be adequate clearance between the oven and combustible construction. Clearance

must also be provided for servicing and for proper operation.

NOTE

An electrical wiring diagram for the oven is located inside the machinery compartment or control

compartment.

NOTE

All aspects of the oven installation, including placement, utility connections, and ventilation requirements,

must conform with any applicable local, national, or international codes. These codes supercede the require-

ments and guidelines provided in this manual.

WARNING

The oven must be installed on an even (level) non-flammable flooring and any adjacent walls must

be non-flammable. Recommended minimum clearances are specified in the Description section of

this Manual.

WARNING -

After any conversions, readjustments, or service work on the oven:

•

Perform a gas leak test.

•

Test for correct air supply, particularly to the burner blower.

•

Test for proper combustion and gas supply.

•

Check that the ventilation system is in operation.

NOTE

In U.S.A., the oven installation must conform with local codes, or in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1. The oven, when installed, must be electrically grounded in accor-

dance with local codes, or in the absence of local codes, with the National Electrical Code (NEC), or ANSI/

NFPA70.

NOTE

In Canada, the oven installation must conform with local codes, or in the absence of local codes, with the

Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Gas Installation Code, CAN/CGA-B149.2,

as applicable. The oven, when installed, must be electrically grounded in accordance with local codes, or in

the absence of local codes, with the Canadian Electrical Code CSA, C22.2, as applicable.

NOTE

For Australian installation, the oven installation must conform with AGA Code, AG601, and with any require-

ments of the appropriate statutory authority.