Atx power supply pwrgood requirements, Figure 72. pull-up resistor example, 2 atx power supply pwrgood requirements – Intel 815 User Manual

Page 145

Advertising
background image

Power Delivery

R

Intel

®

815 Chipset Platform Design Guide

145

A simplistic DC calculation for a pull-up value is:

R

MAX

= (VCC

PU

MIN - V

IH

MIN) / I

LEAKAGE

MAX

R

MIN

= (VCC

PU

MAX - V

IL

MAX) / I

OL

MAX

Since I

LEAKAGE

MAX is normally very small, R

MAX

may not be meaningful. R

MAX

also is

determined by the maximum allowable rise time. The following calculation allows for t, the
maximum allowable rise time, and C, the total load capacitance in the circuit, including the input
capacitance of the devices to be driven, the output capacitance of the driver, and the line
capacitance. This calculation yields the largest pull-up resistor allowable to meet the rise time t.

R

MAX

= -t / (C * In(1-(V

IH

MIN / VCC

PU

MIN) ) )

Figure 72. Pull-Up Resistor Example

Vcc

pu

min.

R

max

V

IH

min.

I

Leakage

max.

Vcc

pu

max.

R

min

V

IL

max.

I

OL

max.

pwr_pullup_res

12.2

ATX Power Supply PWRGOOD Requirements

The PWROK signal must be glitch free for proper power management operation. The ICH sets the
PWROK_FLR bit (ICH GEN_PMCON_2, General PM Configuration 2 Register, PM-dev31:
function 0, bit 0, at offset A2h). If this bit is set upon resume from S3 power-down, the system will
reboot and control of the system will not be given to the program running when entering the S3
state. System designers should insure that PWROK signal designs are glitch free.