Resource name:

The resource name is the symbolic name of the logical hardware

resource. The resource name was either created by the system when the hardware
was first sensed, or was updated to a new value by a user on a change screen. The
logical hardware resource name is autonomous from the packaging hardware
resource name.

Mode:

The mode field indicates whether or not the ownership of this resource

can be switched to another system. The possible values are Private or Switchable.
Private indicates that the ownership of this resource cannot be changed. Switchable
indicates that the ownership of this resource is changeable.

SPCN system information:

Displays the system type and system serial number

for the system providing the SPCN connection for this resource.

Alternate system information:

Displays the system type and system serial

number for a second system (other than the SPCN system) to which this resource
may be connected.

A function key is provided to return to the display HSL Information screen.

Display port information

This display shows the connection information for an HSL loop. For each link, the
display shows information about the connection from the previous resource in the
loop as well as information about the connection to the next resource in the loop.

The fields for this display are as follows:

HSL loop number:

The numerical value of the High Speed Link (HSL) loop to

which the resource belongs.

From and to information:

For each link, the From field shows the connection from

the previous resource in the loop. The To field shows the connection to the next
resource in the loop.

Port Connection Information

HSL loop number . . . . . . . . . : 258

-------From--------

--------To---------

Type of

Resource Name Port

Resource Name Port

Connection

Status

SB01

BC01

Internal

Operational

BC01

A0

BC04

01

External

Failed

BC04

00

BC05

01

External

Unknown

BC05

00

BC02

E1

External

Failed

BC02

E0

BC03

01

External

Operational

BC03

00

SB01

A1

External

Operational

F3=Exit F5=Refresh F6=Print F8=Include non-reporting resources F12=Cancel

Figure 37. Example Port Connection Information display

90