Table 38 on page 193 shows how SRCs are grouped. The SRC is a variable length
structure.

The SRCs are displayed as a sequence of words that may be displayed by selecting
different control panel functions. Function 11 is shown automatically when an SRC
is shown. You may select additional functions through function 20 by using the
Increment/Decrement (

↑ ↓) switches and the Enter button. There is also an option

to include reference code details from the Work with Partition Status display. You
can also select SRC history option from the Display Partition Info menu.

The System Reference Code (SRC) Format Description:

The format of the SRC

that you see depends on the system or server.

For more details about SRCs, refer to the following resources:
1.

iSeries Information Center

2.

iSeries Information Center, System Administration, Availability, and Maintenance
topic (for SRCs related to logical partitions)

3.

Problem Analysis book for your system type (for service representatives)

4.

iSeries Licensed Internal Code Diagnostic Aids - Volume 1, LY44-5900-05 (for service
representatives)

5.

iSeries OS/400 Diagnostic Aids, LY44-5907-05 (for service representatives)

Hardware Related System Reference Code Formats:

Use Table 41 to determine

the SRC format. See “SRC formats” on page 191 for other formats.

Table 41. Hardware-related SRC formats

Word

IOP SRC Format 17 Data

Device SRC Format 27
Data

IOP SRC Format 13 Data

1

TTTT RRRR

tttt rrrr

TTTT RRRR

2

MIGV EP17

MIGV EP27

MIGV EP13

3

BBBB Ccbb

BBBB Ccbb

BBBB Ccbb

4

@@@@ @@@@

@@@@ @@@@

@@@@ @@@@

5

TTTT LMMM

tttt lmmm

TTTT LMMM

6

tttt lmmm

TTTT LMMM

uuuu uuuu

7

ZZZZ rrrr

ZZZZ RRRR

uuuu uuuu

8

ssss ssss

ssss ssss

uuuu uuuu

9

uuuu uuuu

uuuu uuuu

uuuu uuuu

Function 20

Pxxx cccc

Pxxx cccc

Pxxx cccc

The symbols used in Table 41 are defined as follows:

@@@@

Unit address

BBBB Ccbb

Bus, bus, card, and board address (direct select address)

lmmm

Level indicator plus 3+digit model number of failing device

LMMM

Level indicator plus 3+digit model number (for example, 6100 or
6150)

M

Main storage dump indicator

rrrr

Outboard failing unit reference code

Chapter 6. System Reference Code (SRC) Information