Communications signal voltage levels – IBM VERSION 5 SY44-5902-05 User Manual

Page 281

Advertising
background image

Communications signal voltage levels

Table 88. Communications signal voltage levels

Interface type

OFF voltage level

ON voltage level

V.24
EIA-232
X.21bis

Less than -3 volts

More than +3 volts

V.35

When terminated by a 100-ohm resistive
load, the differential voltage (A-B) is 0.55
volts +/- 20%.

When terminated by a 100-ohm resistive
load, the differential voltage (B-A) is 0.55
volts +/- 20%.

Note:

See the V.35 cable to find out which pin numbers are A and B.

X.21

The differential voltage (A-B) is less than
-0.3 volts.

When terminated by a 100 ohm resistive
load, the differential voltage (B-A) is the
larger of 2.0 volts or 50% of the open
circuit voltage. The open circuit voltage is
between 2.0 and 6.0 volts.

The differential voltage (A-B) is more than
+ 0.3 volts.

When terminated by a 100 ohm resistive
load, the differential voltage (A-B) is the
larger of 2.0 volts or 50% of the open
circuit voltage. The open circuit voltage is
between 2.0 and 6.0 volts.

Note:

See X.21 cable diagram to find out which pin numbers are A and B.

ISDN

Logic 0

The differential voltage (A-B) is less than
+.75 volts and more than -.75 volts
(nominal).

Logic 1

The differential voltage (A-B) is 0.0 volts
(nominal).

Chapter 9. System Architecture and Configuration

267

Advertising